PSMW1000 wall cladding system is a structural element for the side (wall) coverage of buildings and for fire resistant partitions. It is composed of two steel sheets separated by a core of mineral wool (100 - 120 kg/m3). The PSMW1000 system is easy and fast to install and offers high thermal/water insulation and resistance to fire.

PSΜW1000 is available in three thicknesses 50mm, 80mm and 100mm.

The panels are produced with pre-painted galvanized steel sheets.

Available lengths from 1 up to 6 meters. For greater/smaller lengths please contact us.

APPLICATIONS

The PSCW1000 wall cladding system can be used in numerous applications such metal buildings, sports facilities, fire resistant partitions, food processing areas, bungalows, mobile homes and many other constructions.

The use of mineral wool core makes the PSMW1000 wall panel particularly useful in application with fire resistance requirements.

DIMENSIONS & WEIGHT

Zoom Weight:

Core thickness (mm) A 50 80 100
Total panel height (mm) Β 50 80 100
Weight kg/m2 (Steel sheet 0.50mm) 14.60 18.20 20.60

Maximum dimension tolerance:

Length L ≤ 3m ±5mm
L > 3m ±10mm
Width ±2mm
Thickness D ≤ 100mm ±2mm

Available lengths:

Available lengths from 1 up to 6 meters. For greater lengths please contact us.

LOAD TABLE

PSMW1000 (ROOF PANEL) SINGLE SPAN SUPPORT MULTIPLE SPAN SUPPORT
PERMISSIBLE LOADS Kg/m2 PERMISSIBLE LOADS Kg/m2
60 80 100 120 150 60 80 100 120 150
50 0,5 3.10 2.50 1.92 1.55 1.16 2.86 2.36 1.96 1.56 11.7
80 0,5 4.12 3.50 3.12 2.65 2.12 4.26 3.76 3.27 2.67 2.13
100 0,5 4.53 4.02 3.52 3.14 2.62 4.66 4.12 3.63 3.23 2.67
L/200

SURFACE

Steel specifications (EN 10327 / EN 10142 / EN 10143)

Quality DX51D
Width 1.080 mm
Thickness 0.50mm – 0.75mm
Zinc coating 100-275 gr/m2
Tensile strength EN 10142

Coating specifications (SP)

Top coat 20 mic.
Primer 5 mic.
Back coat 7 mic.
Gloss 32

For special coatings such as PVDF and HD please contact us.

WATERPROOFING & FASTENING MATERIALS

For the proper installation of all wall panels, we offer a wide range of fixing materials such as self drilling screws and washers. There are also special waterproofing materials available, suitable for highly humid areas (sealant tapes, foam inserts).

We recommend 2 screws / m2.

For screws with higher drilling capacity please contact us.

Πάχος πάνελ (mm) Τύπος βίδας Drilling capacity
50 6.3 x 70mm 8mm
80 6.3 x 100mm 8mm
100 6.3 x 120mm 8mm

FLASHINGS

After installing the panels, customized flashings are necessary in order to waterproof and decorate the construction.

Since every construction has its own needs and finishing details, please get in touch with our technical department in order to customize and apply the flashing details best suited to your needs.

PERFORMANCE

Thermal transmittance (k)

Panel thickness (k) in W/m2K
50 0.74
80 0.47
100 0.38

Reaction to fire (EN 13501-2):

PSMW1000/80mm | 60min.

Core fire class | Α1

ENVIRONMENT

The wall covering system PSMW1000 is produced with environmental friendly materials, is not considered harmful and is fully recyclable.

BALING & TRANSPORT

Baling

The baling of wall panels is fully automated. It is made during the production process and includes placing polystyrene spacers below each bundle and wrapping it with special protection film.

For exports and overseas transport, special baling is available for better protection of the products.

The number of products in each bundle depends on the thickness of the panels and the mode of transport:

Panel thickness 50 80 100
Greece/Cyprus baling (pcs/bundle) 10 7 5

Transport

Transport is usually made on 12-13.5m long platform trucks.If special transport in containers, loose cargo or close TIR trucks is needed, please contact us.

Unloading at sole responsibility of the buyer.

HANDLING & INSTALLATION GUIDE

NOTE:

The information shown contains suggestions or guidelines and is not intended to cover all applications or building requirements. It is the responsibility of the designer/installer to ensure that this information meets particular building conditions and/or code requirements. It is also the responsibility of the installer to ensure that all safety requirements are taken.

GENERAL HANDLING

When handling metal panels, care should be taken to protect the finish from scratching or abrasion. Dragging panels across one another will unnecessarily increase the risk of scratching. Individual panels should be carried vertical to the ground by grasping the edge of the panel.

STORAGE AND PROTECTION

Bundled material should be kept dry and above ground. Material should be tarped (not with plastic) or protected from weather conditions by other means. Allow for proper air circulation to prevent moisture buildup under tarp. Keep bundles slightly inclined to allow for moisture runoff. If the panels become wet, all panels should be removed from bundles and individually dried. Prolonged storage of panels is not recommended. If conditions do not permit immediate installation, extra care should be taken to protect sheets from condensation, developing white/red rust or watermarks.

MECHANICAL HANDLING

A forklift or crane can be used to handle unopened bundles up to 6m in length. For forklift unloading, forks should be spread to maximum width and placed at center line weight distribution of bundle. For crane unloading, a spreader bar should be used to evenly distribute the weight of the bundle. Cable supports or chains will cause damage to the panels and should not be used. Heavy duty straps are recommended.

PANEL INSPECTION

All bundles of panels should be inspected upon delivery from Panelco SA (number of panels, panel condition etc).

FIELD CUTTING

Some field cutting and fitting of panels is to be expected by the installer and minor field corrections are a part of normal installation work. Always cut one panel at a time. For small cuts, hand-held electrical saws are recommended. For best cutting results a panel ribbon saw is recommended. Cutting of panels and driving of fasteners will create metal shavings. These metal shavings must be swept or removed from the panel surface. Failure to do so will cause rust stains on the panel surface.

FASTENING DETAILS

The use of proper fasteners and installation procedures is an important factor in the appearance and performance of the panel system. Roofing and siding may be installed using fasteners with weather seal washers.

PANELCO is not responsible for any claim or claims arising from incorrect handling or installation of products.


 
Linea


Downloads
Sidma
Linea